The Indrion Sync 100 is an intelligent 24V 100Ah LFP battery engineered to deliver safe, dependable and connected energy storage.
|
Parameter |
Specification |
|
Product
Name |
Indrion
Sync 100 |
|
Battery
Chemistry |
Lithium
Iron Phosphate (LFP/LiFePO₄) |
|
Voltage
Architecture |
24V
class |
|
Primary
Applications |
Home
backup, solar storage, small businesses, security systems and telecom
infrastructure |
|
Installation
Type |
Standalone
or parallel-connected battery system |
|
Inverter
Compatibility |
Compatible
with supported standard 24V inverters and UPS systems |
|
Maintenance |
Annual
digital service recommended |
|
Nominal
Voltage |
25.6V |
|
Nominal
Capacity |
100Ah |
|
Nominal
Energy |
2.56kWh |
|
Cell
Configuration |
8
cells in series (4S) |
|
Battery
Operating Voltage Range |
23.2–28.8V |
|
Product
Dimensions |
TBD
after mechanical-design release |
|
Product
Weight |
TBD
after production build |
|
Shipping
Dimensions |
TBD |
|
Shipping
Weight |
TBD |
|
Continuous Charge Current |
80A |
|
Maximum Charge Current |
100A |
|
Continuous Discharge Current |
100A |
|
Peak Discharge Current |
145A |
|
Self-Discharge Rate |
2% per month |
|
Parallel Capability |
Up to 8 compatible batteries |
|
Series Connection |
Not permitted unless specifically
approved |
|
Rated Cycle Life |
3000+ Cycles |
|
Recommended Depth of Discharge |
80% DoD at C/3 at 25°C |
|
End-of-Life Criterion |
80% SOH |
|
Annual Digital Service |
Battery health, diagnostic and
performance review |
|
Battery
Management System |
Intelligent
in-house BMS architecture |
|
Cell-Voltage
Monitoring |
Individual
cell monitoring |
|
Temperature
Monitoring |
Cell
and power-switching-device temperature monitoring |
|
Current
Monitoring |
Charge
and discharge current monitoring |
|
State-of-Charge
Estimation |
Supported |
|
State-of-Health
Estimation |
Supported |
|
Cell
Balancing |
Supported |
|
Cell
Overvoltage Protection |
Supported |
|
Cell
Undervoltage Protection |
Supported |
|
Pack
Overvoltage Protection |
Supported |
|
Pack
Undervoltage Protection |
Supported |
|
Charge
Overcurrent Protection |
Supported |
|
Discharge
Overcurrent Protection |
Supported |
|
Short-Circuit
Protection |
Supported |
|
High-Temperature
Protection |
Supported |
|
Low-Temperature
Protection |
Supported |
|
FET
Temperature Protection |
Supported |
|
Temperature-Sensor
Fault Detection |
Supported |
|
Reverse-Current
Protection |
Supported |
|
Cell-Imbalance
Detection |
Supported |
|
Communication-Fault
Detection |
Supported |
|
Fail-Safe
Operation |
Supported |
|
Fault
Logging |
Supported |
|
Event
Recording |
Supported |
|
Operational Temperature |
0°C to 50°C |
|
High-Temperature Cut-Off |
Above 55°C |